ROYALTON® 14 SEER R-410A Air Conditioning Systems

[tabby title=”Description”]
Experience a cool and comfortable home with this ROYALTON® 14 SEER sweat air conditioning system which is designed and approved for residential and commercial applications. The A/C system consists of the outdoor air conditioning condenser, indoor evaporator coil, and 30 ft. line set, and is designed to be used with a new or existing furnace, or modular air handler – available separately. The condenser is charged with enough R-410A refrigerant to accommodate 15 ft. of line set, and features easy internal access. Top air discharge design and compact cabinet size are great for multi-unit placement outdoors. All systems come with a cased coil filled with dry nitrogen which will be matched to your specific application as a representative will be in contact to help determine the proper coil to be matched with the installation application. The 30 ft. line set is sized appropriately based on the system ton size, and include the liquid line and insulated suction line. All systems are AHRI Certified and ETL listed. Final connections from line set to coil and condenser, and system start-up must be done by a certified technician. Please Note: Due to the Federal Regional Standards for Heating and Cooling Products, customers located in the Southeastern Region consisting of the following states are required to have systems installed that are a minimum of 14 SEER:AL, AK, DE, FL, GA, KY, LA, MD, MS, NC, OK, SC, TN, TX, VA. Customers located in the Southwestern Region consisting of the following states are required to have systems installed that are a minimum of 14 SEER, 12.2 EER ≤ 3.5 tons, 11.7 EER ≥ 4 tons: AZ, CA, NV, NM.

10-Year Limited Parts and Compressor Warranty*

WARNING: Cancer and Reproductive Harm – www.P65Warnings.ca.gov

*Please Note: To qualify for the extended 10-Year Limited Parts Warranty, the unit must be registered online at www.nordynewarranty.com within 60 days of purchase for replacement or closing for new home construction. Otherwise, the standard 5-Year Limited Parts Warranty is in effect.

Condenser Tech Guide

Installation Manual

Manufacturer’s Warranty

[tabby title=”Features”]
Sweat fit system includes outdoor condenser, indoor coil, and line set; a furnace or air handler is required for system operation

Outdoor condenser is pre-charged with enough R-410A refrigerant for a 15 ft. line set; additional charge must be added in the field for longer line set applications

Evaporator coils are available for upflow, downflow, and horizontal installation applications, and must be specified to complete order

The refrigerant piston is included with the condenser and must be field installed into the evaporator coil to achieve proper efficiency and operation

30 ft. line set includes liquid line and insulated suction line

Internally protected scroll compressor to guard against high pressure and temperature

Not for Mobile Home Use

[tabby title=”Sizing Guide”]

HOW TO SELECT A 14 SEER SWEAT-FIT AIR CONDITIONING SYSTEM

You can refer to an estimate or proposal from a local contractor, refer to the size of your existing system that you may want replaced, or use the sizing estimation chart provided on this page. Use the map to determine your Region based on the location of your home. Using the equipment charts, find your Region and go down the column to locate the range that covers the Square Footage of your home. Follow the row to the right to determine the recommended Furnace for your application.

HowToSelect80EfficientFurnaceMap2

 

Square Footage of Your Home A/C System Size
935-1310 800-1235 830-1165 680-955 680-955 1.5 Ton
1310-1680 1235-1580 1165-1500 955-1225 955-1225 2.0 Ton
1680-2060 1580-1940 1500-1830 1225-1500 1225-1500 2.5 Ton
2060-2435 1940-2290 1830-2165 1500-1770 1500-1770 3.0 Ton
2435-2810 2290-2645 2165-2500 1700-2045 1700-2045 3.5 Ton
2810-3375 2645-3175 2500-3000 2045-2455 2045-2455 4.0 Ton
3375-3935 3175-3705 3000-3500 2455-2860 2455-2860 5.0 Ton

 

NOTE: These tables an charts are intended to be used as a guideline only. The information is based on conventional window space (<15%), insulation and builing construction. Only use these tables as a reference. When including a finished basement, use 1/2 of the finished basement square footage with the rest of the area being calculated.

[tabby title=”Models & Specs”]
13 SEER R-410A Air Conditioning Systems

System Model Number Ton Size Compressor Type Max Amps Condenser H x W x D (in.) System Ship Wt. (lbs.) Energy Guide
4AC16L18P 1.5 Scroll 20 29 x 24.25 x 24.25 225 EnergyGuideIcon2
4AC16L24P 2.0 Scroll 25 37 x 28.25 x 28.25 275 EnergyGuideIcon2
4AC16L30P 2.5 Scroll 25 37 x 28.25 x 28.25 305 EnergyGuideIcon2
4AC16L36P 3.0 Scroll 30 37 x 28.25 x 28.25 325 EnergyGuideIcon2
4AC16L42P 3.5 Scroll 40 37 x 28.25 x 28.25 355 EnergyGuideIcon2
4AC16L48P 4.0 Scroll 40 37 x 28.25 x 28.25 365 EnergyGuideIcon2
4AC16L60P 5 Scroll 50 43 x 32.25 x 32.25 385 EnergyGuideIcon2

Optional Air Conditioning Accessories

Item Number Description Weight (lbs.)
ACPD3030-3 3″ H x 30″ W x 30″ D Condenser Pad) 10
ACPD3636-3 3″ H x 36″ W x 36″ D Condenser Pad) 15
WKDP 20 Trim-to-fit Plenum for Cased Coil Applications up to 47″ H x 20″ W x 20″ D 28
1F78-151 5/2 Day Heat/Cool Programmable Thermostat (Single Stage) 1

Upflow Cased Coil Specifications

Model Number Cased Coil H x W x D (in.) Top Opening W x D (in.) Liquid / Vapor Line Connections
EC1P23AL 18.5″ x 14.5″ x 21″ 13″ x 18″ 3/8″ X 3/4″
EC1P23BL 18.5″ x 17.5″ x 21″ 16″ x 18″ 3/8″ X 3/4″
EC1P30AL 24.5″ x 14.5″ x 21″ 13″ x 18″ 3/8″ X 3/4″
EC1P30BL 24.5″ x 17.5″ x 21″ 16″ x 18″ 3/8″ X 3/4″
EC1P30CL 24.5″ x 21″ x 21″ 19.5″ x 18″ 3/8″ X 3/4″
EC1P36AL 24.5″ x 14.25″ x 21″ 13″ x 18″ 3/8″ X 3/4″
EC1P36BL 24.5″ x 17.5″ x 21″ 16″ x 18″ 3/8″ X 3/4″
EC1P36CL 24.5″ x 21″ x 21″ 19.5″ x 18″ 3/8″ X 3/4″
EC1P43BL 29.5″ x 17.5″ x 21″ 16″ x 18″ 3/8″ X 7/8″
EC1P43CL 29.5″ x 21″ x 21″ 19.5″ x 18″ 3/8″ X 7/8″
EC1P49CL 29.5″ x 21″ x 21″ 19.5″ x 18″ 3/8″ X 7/8″
EC1P62CL 31.5″ x 21″ x 21″ 19.5″ x 18″ 3/8″ X 7/8″
EC1P62DL 29.5″ x 24.5″ x 21″ 23″ x 18″ 3/8″ X 7/8″

Horizontal Cased Coil Specifications

Model Number Cased Coil H x W x D (in.) Top Opening W x D (in.) Liquid / Vapor Line Connections
EM1P23AL 25.5 x 14.5 x 21 13 x 19.5 3/8″ X 3/4″
EM1P23BL 25.5 x 17.5 x 21 16 x 19.5 3/8″ X 3/4″
EM1P36AL 25.5 x 14.5 x 21 13 x 19.5 3/8″ X 3/4″
EM1P36BL 25.5 x 17.5 x 21 16 x 19.5 3/8″ X 3/4″
EM1P36CL 25.5 x 21 x 21 19.5 x 19.5 3/8″ X 3/4″
EM1P43BL 27.5 x 17 x 21 16 x 19.5 3/8″ X 7/8″
EM1P43CL 27.5 x 21 x 21 19.5 x 19.5 3/8″ X 7/8″
EM1P48BL 25.5 x 17.5 x21 16 19.5 /span> 3/8″ X 7/8″
EH1P49CM 31.5 x 21 x 21 19.5 x 19.5 3/8″ X 7/8″
EH1P62CM 31.5 x 21 x 21 19.5 x 19.5 3/8″ X 7/8″
EH1P62DM 31.5 x 24.5 x 21 23 x 19.5 3/8″ X 7/8″