[tabby title=”Description”]
Stay cool with this single phase 13 SEER sweat air conditioning system designed for residential applications and consists of the outdoor condenser, indoor coil, and line set. The condenser is charged with R-410A refrigerant and has a top air discharge. The multi-positional fully cased coil is filled with a dry nitrogen, and is to be matched to either the furnace or modular air hanlder width. The Line Set is 30 ft. in length and has a 3/8 in. liquid line and insulated suction line. AHRI Listed and Certified, UL Listed. Final connections from line set to coil and condenser must be done by a certified technician. The system is designed to be used with a new or existing furnace or air handler which is available separately. Please Note: Due to the NEW 2015 Federal Regional Standards for Heating and Cooling Products, customers located in the Southeastern Region consisting of the following states are required to have systems installed that are a minimum of 14 SEER:AL, AR, DE, FL, GA, KY, LA, MD, MS, NC, OK, SC, TN, TX, VA. Customers located in the Southwestern Region consisting of the following states are required to have systems installed that are a minimum of 14 SEER, 12.2 EER ≤ 3.5 tons, 11.7 EER ≥ 4 tons: AZ, CA, NV, NM.
10-Year Limited Parts and Compressor Warranty*
WARNING: Cancer and Reproductive Harm – www.P65Warnings.ca.gov
*Please Note: To qualify for the extended 10-Year Limited Parts Warranty, the unit must be registered online at www.upgproductregistration.com within 90 days of purchase for replacement or closing for new home construction. Otherwise, the standard 5-Year Limited Parts Warranty is in effect.
[tabby title=”Features”]
Sweat fit system includes outdoor condenser, indoor coil, and line set; a furnace or air handler is required for system operation
Outdoor condenser is pre-charged with enough R-410A refrigerant for a 15 ft. line set; additional charge must be added in the field for longer line set applications
Evaporator coil is fully cased and multi-positional for upflow, downflow, and horizontal installation applications
The refrigerant piston is included with the condenser and must be field installed into the evaporator coil to achieve proper efficiency and operation
30 ft. line set includes liquid line and insulated suction line
Internally protected compressor to guard against high pressure and temperature
Not for Mobile Home use
[tabby title=”Sizing Guide”]
HOW TO SELECT A 13 SEER SWEAT-FIT AIR CONDITIONING SYSTEM
You can refer to an estimate or proposal from a local contractor, refer to the size of your existing system that you may want replaced, or use the sizing estimation chart provided on this page. Use the map to determine your Region based on the location of your home. Using the equipment charts, find your Region and go down the column to locate the range that covers the Square Footage of your home. Follow the row to the right to determine the recommended Furnace for your application.
Square Footage of Your Home | A/C System Size | ||||
---|---|---|---|---|---|
935-1310 | 800-1235 | 830-1165 | 680-955 | 680-955 | 1.5 Ton |
1310-1680 | 1235-1580 | 1165-1500 | 955-1225 | 955-1225 | 2.0 Ton |
1680-2060 | 1580-1940 | 1500-1830 | 1225-1500 | 1225-1500 | 2.5 Ton |
2060-2435 | 1940-2290 | 1830-2165 | 1500-1770 | 1500-1770 | 3.0 Ton |
2435-2810 | 2290-2645 | 2165-2500 | 1700-2045 | 1700-2045 | 3.5 Ton |
2810-3375 | 2645-3175 | 2500-3000 | 2045-2455 | 2045-2455 | 4.0 Ton |
3375-3935 | 3175-3705 | 3000-3500 | 2455-2860 | 2455-2860 | 5.0 Ton |
NOTE: These tables an charts are intended to be used as a guideline only for residential applications. The information is based on conventional window space (<15%), insulation and builing construction. Only use these tables as a reference. When including a finished basement, use 1/2 of the finished basement square footage with the rest of the area being calculated.
[tabby title=”Models & Specs”]
13 SEER R-410A Air Conditioning Systems
Optional Air Conditioning Accessories
Item No. | Description | Weight (lbs.) |
---|---|---|
ACPD3030-3 | 3″ x 30″ x 30″ Condenser Pad/span> | 10 |
ACPD3636-3 | 3″ x 36″ x 36″ Condenser Pad) | 15 |
CMP 14 | Plenum for 14.5″ Coil Applications | 24 |
CMP 17 | Plenum for 17.5″ Coil Applications | 26 |
CMP 21 | Plenum for 21″ Coil Applications | 28 |
WKDP 24 | Trim-to-fit-Plenum for 24.5″ Coil Applications | 35 |
1F78-151 | 5/2 Day Heat/Cool Programmable Thermostat (Single Stage) | 1 |
Multi-Positional Cased Coil Specifications
Model Number | Cased Coil H x W x D (in.) | Top Opening W x D (in.) | Liquid / Vapor Line Connections |
---|---|---|---|
CM24ABAA1 | 19.5″ x 14.5″ x 21.5″ | 13.5″ x 19.125 | 3/8″ X 3/4″ |
CM30BBBA1 | 23″ x 17.5″ x 21.5″ | 16.5″ x 19.125 | 3/8″ X 3/4″ |
CM36BBCA1 | 25.625″ x 17.5″ x 21.5″ | 16.5″ x 19.125″ | 3/8″ X 3/4″ |
CM42CBCA1 | 26.75″ x 21″ x 21.5″ | 20″ x 19.125″ | 3/8″ X 7/8″ |
CM48CBCA1 | 33″ x 21″ x 21.5″ | 20″ x 19.125″ | 3/8″ X 7/8″ |
CM60DBDA1 | 32.75″ x 24.5″ x 21.5″ | 23.5″ x 19.125″ | 3/8″ X 7/8″ |
[tabbyending]
Find in Store