10-Year Limited Parts and Compressor Warranty*
WARNING: Cancer and Reproductive Harm – www.P65Warnings.ca.gov
*Please Note: To qualify for the extended 10-Year Limited Parts Warranty, the unit must be registered online at www.upgproductregistration.com within 90 days of purchase for replacement or closing for new home construction. Otherwise, the standard 5-Year Limited Parts Warranty is in effect.
Outdoor condenser is pre-charged with enough R-410A refrigerant for a 15 ft. line set; additional charge must be added in the field for longer line set applications
The fully cased evaporator coil comes with a factory installed TXV, thermal expansion valve, is fully cased, and the multi-positional design allows it to be installed for upflow, downflow, and horizontal applications
30 ft. line set includes liquid line and insulated suction line
Internally protected compressor to guard against high pressure and temperature
Not for Mobile Home use
HOW TO SELECT A 14 SEER SWEAT-FIT AIR CONDITIONING SYSTEM
You can refer to an estimate or proposal from a local contractor, refer to the size of your existing system that you may want replaced, or use the sizing estimation chart provided on this page. Use the map to determine your Region based on the location of your home. Using the equipment charts, find your Region and go down the column to locate the range that covers the Square Footage of your home. Follow the row to the right to determine the recommended Furnace for your application.
Square Footage of Your Home | A/C System Size | ||||
---|---|---|---|---|---|
935-1310 | 800-1235 | 830-1165 | 680-955 | 680-955 | 1.5 Ton |
1310-1680 | 1235-1580 | 1165-1500 | 955-1225 | 955-1225 | 2.0 Ton |
1680-2060 | 1580-1940 | 1500-1830 | 1225-1500 | 1225-1500 | 2.5 Ton |
2060-2435 | 1940-2290 | 1830-2165 | 1500-1770 | 1500-1770 | 3.0 Ton |
2435-2810 | 2290-2645 | 2165-2500 | 1700-2045 | 1700-2045 | 3.5 Ton |
2810-3375 | 2645-3175 | 2500-3000 | 2045-2455 | 2045-2455 | 4.0 Ton |
3375-3935 | 3175-3705 | 3000-3500 | 2455-2860 | 2455-2860 | 5.0 Ton |
NOTE: These tables an charts are intended to be used as a guideline only. The information is based on conventional window space (<15%), insulation and builing construction. Only use these tables as a reference. When including a finished basement, use 1/2 of the finished basement square footage with the rest of the area being calculated.
Optional Air Conditioning Accessories
Item No. | Description | Weight (lbs.) |
---|---|---|
ACPD3030-3 | 3″ x 30″ x 30″ Condenser Pad/span> | 10 |
ACPD3636-3 | 3″ x 36″ x 36″ Condenser Pad) | 15 |
CMP 14 | Plenum for 14.5″ Coil Applications | 24 |
CMP 17 | Plenum for 17.5″ Coil Applications | 26 |
CMP 21 | Plenum for 21″ Coil Applications | 28 |
WKDP 24 | Trim-to-fit-Plenum for 24.5″ Coil Applications | 35 |
1F78-151 | 5/2 Day Heat/Cool Programmable Thermostat (Single Stage) | 1 |
Multi-Positional Cased Coil Specifications
Model Number | Cased Coil H x W x D (in.) | Top Opening W x D (in.) | Liquid / Vapor Line Connections |
---|---|---|---|
CM24ABAA1 | 19.5″ x 14.5″ x 21.5″ | 13.5″ x 19.125 | 3/8″ X 3/4″ |
CM30BBBA1 | 23″ x 17.5″ x 21.5″ | 16.5″ x 19.125 | 3/8″ X 3/4″ |
CM36BBCA1 | 25.625″ x 17.5″ x 21.5″ | 16.5″ x 19.125″ | 3/8″ X 3/4″ |
CM42CBCA1 | 26.75″ x 21″ x 21.5″ | 20″ x 19.125″ | 3/8″ X 7/8″ |
CM48CBCA1 | 33″ x 21″ x 21.5″ | 20″ x 19.125″ | 3/8″ X 7/8″ |
CM60DBDA1 | 32.75″ x 24.5″ x 21.5″ | 23.5″ x 19.125″ | 3/8″ X 7/8″ |